Technical specification
Load-bearing capacity (EN 1398) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 kN
Construction height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 mm
Lip length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 mm
Lip chamfer angle (on sides) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 mm
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,75 kW
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . 400 V / 50 Hz / 2,5 A
Control current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .. . . . . 24 V DC
Protection class (ref. to control panel) . . . . . . . . . . . . . . . .. .. . . . . . . IP 54
Hydraulic working pressure . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . abt. 70 bar
Outside diameter of the main cylinder . . . . . . . . . . . . . . . . . . . . . . . . 65 mm
Outside diameter of the lip cylinder . . . . . . . . . . . . . . .. . . . . . . . . . . . 45 mm
Working temperatures . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . from –30O do +50OC
Standard colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RAL 9005 (black)
Draught seals (side and back) . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . .standard

INSTALLATION
GUIDELINES
TECHNICAL
CARDS
BIM
LIBRARIES
2D
LIBRARIES

Dock levellers are designed to bridge the difference in height between the warehouse and the vehicle.
The PowerRamp 233NG is the newest generation electro hydraulic dock leveller including a sliding (telescopic) lip. The platform as well as the lip is driven hydraulically.
Technical specification
Capacity (EN 1398) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 kN
Construction height . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 mm
Lip length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . 0-500 mm
Lip chamfer angle (on sides) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(abt. 5O) 25 mm
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,75 kW
Power supply . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . .. . . . . . . . . . . . . . . . .400 V / 50 Hz / 2,5 A
Control current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V DC
Protection class of the control panel . . . . .. . . . . . . .. . . . . . . . . . . . . . . .IP 54
Working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . abt. 100 bar
Outside diameter of the main cylinder . . . . . . . . . . . . . . . . . .. . . . . . . . 65 mm
Outside diameter of the lip cylinder . . . . . . . . . . . . . . . . . . . . .. . . . . .. . 50 mm
Working temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . from –30O to +50OC
Standard colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . RAL 9005 (black)
Draught seals (side and back) . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .standard

INSTALLATION
GUIDELINES
TECHNICAL
CARDS
BIM
LIBRARIES
2D
LIBRARIES

The PowerShelter 403M is a dock shelter which uses a sturdy curtain made from durable material for the closing of the area between the opening of the warehouse and the docked vehicle.
Technical specification
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3400 mm
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3400 mm
Depth (projection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 mm
Width of side curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 mm
Height of top curtain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 mm
Installation height (above the height of the highest vehicle) . . . . . 500 mm
Curtain fabric . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . 3000 g/m2
Standard colour . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . .. . . . . . . . . . . . . RAL 9005 (black)

INSTALLATION
GUIDELINES
TECHNICAL
CARDS
BIM
LIBRARIES
2D
LIBRARIES

The latest generation inflatable dock shelter:
-Attractive aesthetic finish
-Energy efficient
-Robust cushions made of durable and high quality material, folded nicely
-Ideally suited for conditioned environments
-Folded cushions are stowed behind protective strips
-Efficient and durable seal

Technical specification
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3500 mm
Height . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 3700 mm
Depth (projection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 mm
Protection stripes (side cushions width) . . . . . . . . . . . . . .. . . . . . . 250 mm
Protection stripes (top cushions height) . . . . . . . . . . . . .. . . . . . . . 400 mm
Installation height (recommended) . . . . . . . . . . . . . . . . . . . . . . . . . 4700 mm
Cushion fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670 g/m2
Side cushion width (inflated) . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . 600 mm
Top cushion depth (inflated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100 mm
Inflation time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 seconds
Deflation time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 seconds
Control panel protection class . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . IP65
Power supply . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . 230V / 0,25 kW
Control current . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . 24V DC
Working temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from –35O to +80OC
Colour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . RAL 9005 (black)

INSTALLATION
GUIDELINES
TECHNICAL
CARDS
BIM
LIBRARIES
2D
LIBRARIES

Safe and precise vehicle docking at the place of loading is ensured by wheel guides.
Wheel guides provide for precise vehicle docking, and eliminate possibility of loading system, warehouse and vehicle damage.

Wheel guides are made of hot dip galvanized pipe.
Models available:
• to be concreted – model 970-013 (pipes: diameter 160 [mm] and length 1920 [mm]),
• to be screwed to the floor with fastening pins – flanged version (model 970-011: pipes diameter is 160 [mm] and length is 1920 [mm])

INSTALLATION
GUIDELINES
TECHNICAL
CARDS
BIM
LIBRARIES
2D
LIBRARIES

Bumpers provide additional protection of the loading station and vehicle against damages. Bumpers absorb power in case the docking vehicle pushes against the reloading station
Technical specification

Rubber bumper RB 300
Made of solid rubber, with two installation holes.
Dimensions: 250 x 300 x 100 [mm].

Rubber bumper RB 500
Made of solid rubber, with two installation holes.
Dimensions: 250 x 500 x 100 [mm].